Item | Description | Status |
|
|
|
11 | Single bit error | Amber = Single bit error limit has been |
|
| exceeded |
|
| Off = Normal |
|
|
|
12 | System fan failure | Amber = System fan has failed or is missing |
|
| Off = Normal |
|
|
|
System LEDs and internal health LED combinations
When the internal health LED on the front panel illuminates either amber or red, the server is experiencing a health event. Combinations of illuminated system LEDs and the internal health LED indicate system status.
NOTE: The system management driver must be installed for the internal system health LED to provide pre- failure and warranty conditions.
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM ("HP Insight Diagnostics" on page 46) may report server status differently than the health LEDs because the software tracks more system attributes.
System LED and color | Internal health LED | Status |
| color |
|
|
|
|
Processor failure, | Red | One or more of the following conditions may exist: |
socket X (Amber) |
| • Processor in socket X has failed. |
|
| |
|
| • Processor X is not installed in the socket. |
|
| • ROM detected a failed processor during POST. |
|
|
|
| Amber | Processor in socket X is in a |
|
|
|
PPM failure, slot X | Red | • PPM in slot X has failed. |
(Amber) |
| • PPM is not installed in slot X, but the corresponding |
|
| |
|
| processor is installed. |
|
|
|
DIMM failure, slot X | Red | • DIMM in slot X has failed. |
(Amber) |
| • DIMM has experienced a |
|
| |
|
|
|
| Amber | • DIMM in slot X has reached |
|
| error threshold. |
|
| • DIMM in slot X is in a |
|
|
|
DIMM bank error (all | Red | The bank is not populated entirely or DIMMs do not all |
slots in one bank, |
| match within the bank. |
Amber) |
|
|
DIMM failure (all | Red | • No valid or usable memory is installed in the system. |
slots, Amber) |
| • The banks are not populated in the correct order. |
|
| |
|
|
|
System temperature | Red | System temperature has exceeded OS cautionary level or |
alert (Amber) |
| critical hardware level. |
|
|
|
Fan (Amber) | Red | A required fan has failed. |
|
|
|
Component identification 54