36.SCREEN WIPER Set
Function
The external control equipment sets the SCREEN WIPER of the plasma monitor.
Transmission Data
| DFH 80H 60H C8H 04H | DATA00 to DATA03 CKS |
| ||
| DATA00 : SCREEN WIPER | 00H | : No operation | ||
|
| 01H | : ON | ||
|
| 02H | : OFF | ||
| DATA01 : WORKING TIME | 00H | : ON | ||
|
| 01H: 03M (minutes) | |||
|
| 02H: 06M (minutes) | |||
|
| : |
|
|
|
|
| FFH: 12H (hours) and 45M (minutes) | |||
| DATA02 : WAITING TIME | 01H: 03M (minutes) | |||
|
| 02H: 06M (minutes) | |||
|
| : |
|
|
|
|
| FFH: 12H (hours) and 45M (minutes) | |||
| DATA03 : SPEED | 01H | : 1 |
| |
|
| : |
|
|
|
|
| 05H | : 5 |
| |
ACK |
|
|
|
| |
|
|
|
|
|
|
| 3FH 60H 80H C8H 00H | CKS |
|
|
NOTE: The WORKING TIME and the WAITING TIME can be set in units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
35