37.ALL RESET

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH 80H 60H 54H 00H CKS

ACK

3FH 60H 80H 54H 00H CKS

38.Audio Select Set

Function

The external control equipment sets combinations of audio and video inputs for the plasma monitor.

Transmission Data

DFH 80H 60H 70H 02H

DATA00 DATA01 CKS

 

DATA00 : AUDIO INPUT

01H : AUDIO1

 

02H : AUDIO2

 

03H : AUDIO3

DATA01 : VISUAL INPUT

01H : VIDEO1

 

02H : VIDEO2

 

03H : VIDEO3

 

05H

: HD(HD1 or DTV or DTV1)

 

06H

: HD2(DTV2)

 

07H

: RGB1/PC1

 

08H

: RGB2/PC2

 

0CH : RGB3/PC3

 

0DH : HD3(SCART3)

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 70H 00H CKS

*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.

Example:

The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.