37.ALL RESET
Function
The external control equipment resets the user adjustment of the plasma monitor.
Transmission Data
1FH 80H 60H 54H 00H CKS
ACK
3FH 60H 80H 54H 00H CKS
38.Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs for the plasma monitor.
Transmission Data
DFH 80H 60H 70H 02H | DATA00 DATA01 CKS |
| |
DATA00 : AUDIO INPUT | 01H : AUDIO1 | ||
| 02H : AUDIO2 | ||
| 03H : AUDIO3 | ||
DATA01 : VISUAL INPUT | 01H : VIDEO1 | ||
| 02H : VIDEO2 | ||
| 03H : VIDEO3 | ||
| 05H | : HD(HD1 or DTV or DTV1) | |
| 06H | : HD2(DTV2) | |
| 07H | : RGB1/PC1 | |
| 08H | : RGB2/PC2 | |
| 0CH : RGB3/PC3 | ||
| 0DH : HD3(SCART3) |
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 70H 00H CKS
*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.
36