35.INVERSE Set

Function

The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasma monitor.

Transmission Data

 

DFH 80H 60H C7H 03H

DATA00 DATA01 DATA02 CKS

 

 

DATA00: INVERSE/WHITE

00H

: No operation

 

 

01H

: ON (INVERSE)

 

 

02H

: OFF

 

 

03H

: WHITE

 

DATA01 : WORKING TIME

00H

: ON

 

 

01H: 03M (minutes)

 

 

02H: 06M (minutes)

 

 

:

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

 

DATA02 : WAITING TIME

01H: 03M (minutes)

 

 

02H: 06M (minutes)

 

 

:

 

 

 

 

 

FFH: 12H (hours) and 45M (minutes)

ACK

 

 

 

 

 

 

 

 

 

 

 

3FH 60H 80H C7H 00H

CKS

 

 

NOTE: The WORKING TIME and the WAITING TIME can be set in units of 3 minutes.

Example: 03H=9 minutes

1EH=1 hour and 30 minutes

34