31.POWER MGT Select

Function

The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.

Transmission Data

 

DFH 80H 60H 1AH 02H

DATA00

DATA01

CKS

 

 

DATA00 : POWER MGT Select

03H

 

 

 

 

 

DATA01

01H

: ON

 

 

 

 

 

02H

: OFF

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

7FH 60H 80H 1AH 02H

DATA00

DATA01

CKS

 

DATA00 : POWER MGT Select

03H

 

 

 

 

 

DATA01

01H

: ON

 

 

 

 

 

02H

: OFF

 

 

32.GRAY LEVEL Set

Function

The external control equipment sets the GRAY LEVEL of the plasma monitor. Transmission Data

 

DFH 80H

60H C6H 01H

DATA00 CKS

 

 

DATA00 : GRAY LEVEL

00H : 0

 

 

 

 

:

 

 

 

 

 

0FH : 15

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH 60H

80H

C6H 01H

DATA00 CKS

 

DATA00 : GRAY LEVEL

00H : 0

 

 

 

 

:

 

 

 

 

 

0FH : 15

32