29.OSM Select

Function

The external control equipment switches on or off the on-screen menu (OSM) of the plasma monitor.

Transmission Data

 

DFH 80H

60H 58H 01H DATA00 CKS

 

 

DATA00:

01H: On-Screen menu On

 

 

02H: On-Screen menu Off

ACK

 

 

 

 

 

 

 

7FH 60H

80H 58H 01H DATA00 CKS

 

DATA00:

01H: On-Screen menu On

 

 

02H: On-Screen menu Off

*Operation is as described in the table below.

 

 

 

On-Screen Menu (OSM)

 

Operation

Display of items and adjustments

Volume display, input display, and

 

on the menu

screen size display

 

When

screen

When screen

When screen

When screen

 

menu is ON

menu is OFF

menu is ON

menu is OFF

Remote

 

Yes

Yes

Yes

No

control

 

 

 

 

 

operation

 

 

 

 

 

Personal

 

No

No

Yes

No

computer

 

 

 

 

 

control

 

 

 

 

 

operation

 

 

 

 

 

30.OSM ADJ. Gain Data

Function

The external control equipment sets the position of the OSM menu of the plasma monitor.

Transmission Data

 

DFH 80H

60H 1AH 02H

DATA00 DATA01 CKS

 

DATA00 : OSM ADJ. Gain Flag

02H

 

DATA01

 

01H : 1

 

 

 

:

 

 

 

 

06H : 6

ACK

 

 

 

 

 

 

 

 

7FH 60H

80H 1AH 01H DATA00 CKS

 

DATA00 : OSM ADJ. Gain Flag

02H

 

 

 

31