25.H-WIDTH Gain Data

Function

The external control equipment changes the H-WIDTH gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01 DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

03H

 

 

 

DATA01 : H-WIDTH Gain Flag

08H

 

 

 

DATA02 : H-WIDTH Gain

00H

: 0

 

 

 

:

 

 

 

 

40H

: +64

 

ACK

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

03H

 

 

 

DATA01: H-WIDTH Gain Flag

08H

 

 

26.AUTO PICTURE Select

Function

The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00

DATA01

DATA02

CKS

 

DATA00 : USER PICTURE Gain Flag

03H

 

 

 

DATA01 : AUTO PICTURE Select Flag

09H

 

 

 

DATA02 00H : ON

 

 

 

 

 

01H

: OFF

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

7FH

60H 80H 7FH 03H DATA00

DATA01

DATA02

CKS

 

DATA00 : USER PICTURE Gain Flag

03H

 

 

 

DATA01 : AUTO PICTURE Select Flag

09H

 

 

 

DATA02 00H

: ON

 

 

 

 

 

01H

: OFF

 

 

 

29