25.
Function
The external control equipment changes the
Transmission Data
| DFH 80H 60H 7FH 03H DATA00 | DATA01 DATA02 CKS | ||
| DATA00 : USER PICTURE Gain Flag | 03H |
|
|
| DATA01 : | 08H |
|
|
| DATA02 : | 00H | : 0 |
|
|
| : |
|
|
|
| 40H | : +64 |
|
ACK |
|
|
| |
|
|
| ||
| 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS | |||
| DATA00: USER PICTURE Gain Flag | 03H |
|
|
| DATA01: | 08H |
|
|
26.AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
| DFH 80H 60H 7FH 03H DATA00 | DATA01 | DATA02 | CKS | ||
| DATA00 : USER PICTURE Gain Flag | 03H |
|
| ||
| DATA01 : AUTO PICTURE Select Flag | 09H |
|
| ||
| DATA02 00H : ON |
|
|
| ||
|
| 01H | : OFF |
|
|
|
ACK |
|
|
|
| ||
|
|
|
|
|
| |
| 7FH | 60H 80H 7FH 03H DATA00 | DATA01 | DATA02 | CKS | |
| DATA00 : USER PICTURE Gain Flag | 03H |
|
| ||
| DATA01 : AUTO PICTURE Select Flag | 09H |
|
| ||
| DATA02 00H | : ON |
|
|
| |
|
| 01H | : OFF |
|
|
|
29