23.H.POSITION Gain Data

Function

The external control equipment changes the H. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

03H

 

 

 

DATA01 : H.POSITION Gain Flag

02H

 

 

 

DATA02 : H.POSITION Gain

80H

: -128

 

 

 

:

 

 

 

 

FFH : -01

 

 

00H

: 0

 

 

 

01H

: +01

 

 

 

:

 

 

 

 

7FH : +127

ACK

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00

DATA01 CKS

 

DATA00: USER PICTURE Gain Flag

03H

 

 

 

DATA01: H.POSITION Gain Flag

02H

 

 

24.V-HEIGHT Gain Data

Function

The external control equipment changes the V-HEIGHT gain data of the plasma monitor.

Transmission Data

 

DFH 80H 60H 7FH 03H DATA00 DATA01

DATA02 CKS

 

DATA00 : USER PICTURE Gain Flag

03H

 

 

 

DATA01 : V-HEIGHT Gain Flag

07H

 

 

 

DATA02 : V-HEIGHT Gain

00H : 0

 

 

 

 

:

 

 

 

 

40H : +64

ACK

 

 

 

 

 

 

 

 

7FH 60H 80H 7FH 02H DATA00 DATA01

CKS

 

DATA00: USER PICTURE Gain Flag

03H

 

 

 

DATA01: V-HEIGHT Gain Flag

 

07H

28