23.H.POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
| DATA00 : USER PICTURE Gain Flag | 03H |
|
|
| DATA01 : H.POSITION Gain Flag | 02H |
|
|
| DATA02 : H.POSITION Gain | 80H | : |
|
|
| : |
|
|
|
| FFH : | ||
|
| 00H | : 0 |
|
|
| 01H | : +01 |
|
|
| : |
|
|
|
| 7FH : +127 | ||
ACK |
|
|
| |
|
|
|
| |
| 7FH 60H 80H 7FH 02H DATA00 | DATA01 CKS | ||
| DATA00: USER PICTURE Gain Flag | 03H |
|
|
| DATA01: H.POSITION Gain Flag | 02H |
|
|
24.
Function
The external control equipment changes the
Transmission Data
| DFH 80H 60H 7FH 03H DATA00 DATA01 | DATA02 CKS | ||
| DATA00 : USER PICTURE Gain Flag | 03H |
|
|
| DATA01 : | 07H |
|
|
| DATA02 : | 00H : 0 |
|
|
|
| : |
|
|
|
| 40H : +64 | ||
ACK |
|
|
| |
|
|
|
| |
| 7FH 60H 80H 7FH 02H DATA00 DATA01 | CKS | ||
| DATA00: USER PICTURE Gain Flag | 03H |
|
|
| DATA01: |
| 07H | |
28 |
|
|
|