63.GAMMA GAIN Data
Function
External control apparatus changes Gamma of a plasma monitor. Transmission Data
DFH 80H 60H 13H 02H DATA00 DATA01 CKS
| DATA00: GAMMA FLAG | 01H | : Gamma change | |
| DATA01: GAMMA | 00H | :1 |
|
|
| 01H | :2 |
|
|
| 02H | :3 |
|
|
| 03H | :4 |
|
ACK |
|
|
| |
|
|
| ||
| 7FH 60H 80H 13H 01H DATA00 CKS | |||
| DATA00: GAMMA FLAG | 01H | : Gamma change |
64.Running Sense
Function
External control apparatus grasps the power supply state of a plasma monitor. A plasma monitor is made to recognize connection of PC CONTROL. Transmission Data
1FH 80H 60H 88H 00H CKS
ACK
7FH 60H 80H 88H 01H DATA CKS
DATA: Bit0:Connect Condition
0:No connection
1:Connected
Bit1 0: Fixed
1:-
Bit2:Power Status
0:POWER ON
1:POWER OFF(STANBY)
Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed