61.POWER DELAY ON(at 4 or 9 multiscreen)

Function

External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply.

Transmission Data

DFH 80H 60H F2H 01H DATA00 CKS DATA00: 00H-FFH: Delay time (second)

*: This command is premised on two or more plasma monitor system composition being multi-systems. In command issue of master1 OSD operation, the value of DATA00 is 01H (1 second). This command does not have ACK for one-way traffic.

*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.

62.POWER DELAY ON (at 16 or 25 multi screens)

Function

External control apparatus attaches a time lag to 10 or more plasma monitors, and turns on a power supply.

Transmission Data

DFH 80H 60H F6H 01H DATA00 CKS

 

DATA00: 01H

mode1

 

02H

mode2

ACK

 

 

 

 

7FH 60H 80H F6H 01H DATA00 CKS

 

DATA00: 01H

mode1

 

02H

mode2

NOTE: When multi mode is 16 or 25, this function is available.