66.OSM OBITER
Function
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.
Transmission Data
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H : OBITER ON 02H : OBITER OFF
ACK
7FH 60H 80H 5FH 01H DATA00 CKS
DATA00 01H : OBITER ON 02H : OBITER OFF
67.OSM ANGLE
Function
The vertical display of OSM and a horizontal display are chosen. Transmission Data
| DFH | 80H | 60H | 60H | 01H | DATA00 | CKS | |
| DATA00 | 01H | : Horizontal display |
|
| |||
|
|
| 02H | : Vertical display |
|
| ||
ACK |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 7FH | 60H | 80H | 60H | 01H | DATA00 | CKS | |
| DATA00 | 01H | : Horizontal display |
|
| |||
|
|
| 02H | : Vertical display |
|
|
68.Input Skip
Function
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.
Transmission Data
DFH 80H 60H 61H 01H DATA00 CKS
DATA00 01H : ON 02H : OFF
ACK
7FH 60H 80H 61H 01H DATA00 CKS
DATA00 01H : ON 02H : OFF
65