Pitco Frialator L20-299 operation manual Installation/Operation, Main Burner System Adjustment

Models: L20-299

1 20
Download 20 pages 45.37 Kb
Page 9
Image 9

INSTALLATION/OPERATION

Main Burner System Adjustment

For the main burners to operate the gas supply valve must be open and the thermostat must be turned on. For models with electric controls, the main power switch must be on. The main burners receive gas from the main gas supply through the thermostatically controlled valve. When the thermostat is turned up the gas control valve opens.

The main burners must be adjusted to deliver optimum flame. Refer to the following procedure to adjust the main burners.

CAUTION

Before proceeding any further, fill the tank with WATER. Water is used for the installation

adjustments because the temperature will never exceed 212°F (100°C), thereby allowing plenty of adjustment time. Never let the water level go below the “OIL LEVEL” mark stamped on the tank.

a.Ensure that the main gas valve is shut off, remove the manifold pressure tap plug and connect an accurate pressure gauge (range of 0-16 “ w.c. in 0.1” increments) or manometer.

b.Turn on this and all appliances connected to the gas supply line and light their main burners. The pressure reading of the installed pressure gauge should not drop from the required installation pressure. Any loss of pressure indicates inadequate supply line installation, which will cause poor performance of all appliances during peak usage.

c.The installed pressure gauge should be the same, ±0.1” w.c, as that marked on the data plate on the inside door or on the back of the appliance. If the pressure is correct, go to step e, if it is not, adjust the pressure as outlined in step d.

d.To adjust the pressure, remove the regulator adjustment screw cap and, with a flat head screwdriver, adjust the regulator screw until the proper burner pressure is reached. Turning the screw clockwise will increase the burner pressure. Turning the screw counterclockwise will decrease the burner pressure.

e.When the pressure is correct, replace the regulator adjustment screw cover.

6

Page 9
Image 9
Pitco Frialator L20-299 operation manual Installation/Operation, Main Burner System Adjustment