Pitco Frialator PPE14-L, and RSE14 manual 1.3.4Ventilation and Fire Fighting System

Models: and RSE14 PE14 PPE14-L

1 26
Download 26 pages 6.05 Kb
Page 13
Image 13

Table 1-1. Electrical Requirements For Pasta Perfect Cooker Models

Model

Voltage and

 

Number

Phase Arrangement

Line Current

 

 

 

PE14 with

220 VAC

23.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

PE14 with

240 VAC

25.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

PE14 without

200 VAC

27.8 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

PE14 without

208 VAC

28.9 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

PE14 without

220 VAC

23.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

PE14 without

240 VAC

25.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

 

 

 

 

1.3.4Ventilation and Fire Fighting System

1.3.4.1Fire Fighting System - It is very important to install an adequate fire fighting system. The sensing device that activates the fire fighting system should be located according to manufactures recommendations to reduce false alarms.

1.3.4.2Ventilation - The Pasta cooker must have proper ventilation to function safely and properly. The ventilation system should be designed to allow for easy cleaning. Frequent cleaning of the ventilation system and the cooker will reduce the chances of fire. Table 1-2 provides a list of reference documents that provide guidance on ventilation and fire safety systems. This table may not be complete and other nationally recognized standards may apply.

1-5

Page 13
Image 13
Pitco Frialator PPE14-L, and RSE14 manual 1.3.4Ventilation and Fire Fighting System