Reliability

The MTBF (mean time between failure) is a minimum of 50,000 hours at 25°C ambient, except for performance characteristics with an otherwise specified life expectancy.

Safety and EMI

The display will not inhibit the end product from obtaining these certifications:

Safety

UL544, IEC950

EMI

FCC Part 15/J, Class B

 

EN55022 Level B

Environmental

Table 7. Environmental Characteristics.

Temperature

Operating

-5 to +55°C

 

Non-Operating

-40 to +75°C

 

Operating Survival

-20 to +65°C

 

 

 

 

Humidity

 

 

Non-condensing

93% RH max, @ 40°C

per IEC 68-2-3.

 

 

 

Altitude

 

 

Operating

0 to 5 km (16k ft)

per IEC 68-2-13.

Non-Operating

0 to 18 km (58k ft)

 

 

 

 

Vibration

 

 

Random

0.05 g²/Hz

ASD level, 20-500 Hz per

 

 

IEC 68-2-36, test Fdb

 

 

 

Shock

 

 

Half sine wave

100 g, 4 ms

18 (3 each, 6 surfaces) per

 

 

IEC 68-2-27, test Ea

 

 

 

EL640.480-AF1 VGA Operations Manual (020-0349-00A)

11

Page 13
Image 13
Planar EL640.480-AF1 user manual Reliability, Safety and EMI, Environmental Characteristics