Operational Specifications

Operational Specifications

Environmental

Table 6. Environmental Characteristics.

Temperature

Operating

–25…+65°C

Non-operating

–40…+85°C

Operating Survival

–40…+70°C (no permanent damage)

Humidity

 

Relative Humidity

+40°C, 93% RH, Operating (IEC 68-2-3)

Damp Heat

+25…+55°C, 95% RH, Non operating (IEC 68-2-30)

 

 

Altitude

 

 

15,000 m (50,000 ft.) above sea level

 

Standard IEC 68–2–13

 

 

Vibration

 

 

20…500 Hz

 

ASD level 0.05 g2/Hz

 

30 min each axis

 

Standard IEC 68–2–36, Random Vibration, Test Fdb

Shock

 

Magnitude

100 g

Duration

4 ms (half sine wave)

Number of shocks

18 (3 on each of the 6 surfaces) IEC 68-2-27, test Ea

Reliability

MTBF > 50,000 h @ 25°C, @ 120 Hz

Safety

The display will not inhibit the end product from obtaining any of the following certifications: UL544, IEC 950.

Electromagnetic Compatibility

The display is capable of operating in an end product that complies with:

EN55022 Class B, FCC Part 15J Class B.