INDOOR UNIT

ELECTRICAL CONNECTIONS FOR INDOOR AND OUTDOOR UNITS

INDOOR UNIT

1.The indoor unit is powered from the outdoor unit. A sufficient length of conduit and wiring shall be used from the outdoor unit to the indoor unit.

2.To access the terminal block inside the indoor unit, remove the screw on the cover plate. (See Fig. A.)

3.Connect the inter unit conductors to terminals marked 1,2,3, OUTDOOR UNIT on the indoor unit corresponding to the same numbered terminals from the outdoor unit. (See Fig.B.)

Figure A

Terminal block

 

Figure B

Terminal block of indoor unit

Cover plate

OUTDOOR UNIT

1.Two conduit connection openings are provided on the outdoor unit: one for incoming power supply and the second one for the inter unit wiring.

2.Remove the terminal box cover to access the terminal block.

3.Connect the power supply conductors to terminal marked L1, N or L1, L2, and the grounding wire to terminal marked Installation & service manual _8.

4.Connect the inter unit conductors to terminals marked Manual background, 3, 2, 1.

9SRA-HE 12SRA-HE 15SRA-HE (115V - 60Hz)

18SRA-HE 24SRA-HE (208-230V - 60Hz)

ConduitConduit connectors

Incoming power supply

To indoor unit

ConduitConduit connectors

Incoming power supply

To indoor unit

Installation & service manual _8