REFRIGERATION LINE CONNECTIONS
When connecting the refrigerant tubing
-Keep all tubing runs as short as possible.
-Use the flare method for connecting tubing.
-Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a
-Check carefully for leaks before starting the test run.
|
| Compressor |
|
|
|
| |
Indoor unit | Evaporator | Condenser | Outdoor unit |
|
|
| |
|
| Capillary tube |
|
Models |
|
| |||||
|
|
|
|
|
|
|
|
Refrigeration Tubing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection method |
|
| Flare | Flare | Flare | Flare | Flare |
|
|
|
|
|
|
|
|
Refrigerant tube outer diameter | in. | Liquid | 1/4 | 1/4 | 1/4 | 1/4 | 3/8 |
|
|
|
|
|
|
|
|
| in. | Suction | 1/2 | 1/2 | 1/2 | 5/8 | 5/8 |
|
|
|
|
|
|
|
|
Limit of tubing length | ft. |
| 49 | 49 | 49 | 49 | 49 |
|
|
|
|
|
|
|
|
Limit of elevation difference between the two units | ft. |
| 20 | 20 | 20 | 20 | 20 |
|
|
|
|
|
|
|
|