INSTALLATION RECOMMENDATIONS (INDOOR UNIT)
1.Before fixing the installation plate to a wall, you must determine the position of the 2 3/4 in (70 mm) hole through which the conduit, piping and drain hose pass to connect the indoor unit to the outdoor unit. The piping and conduit can be con- nected from the: Rear, Right or Left side of indoor unit.
INCORRECT
CORRECT
2.Determine the position of the pipe and drain hose hole using one of the figures shown, and drill the hole with an inner diameter of 70 mm (2 3/4 inch) so that it slants slightly downwards.
3. The correct mounting of the indoor unit is as shown below.
2 3/8 in minimum
Left side 2 in
minimum
Right side 2 in minimum
59 in minimum
59 to 79 in minimum
POSITION THE MOUNTING PLATE LEVEL
CORRECT INCORRECT INCORRECT
Caution:
Take servicing into consideration and leave the spacing shown in the figure above. Also install the unit where it can be removed.