When an Indicator is Lit or Blinking

When an Indicator is Lit or Blinking

The indicators on the projector’s control panel lit or blink to notify of problems, as described below.

An indicator is also used to notify you of the currently set power mode (under normal circumstances). See “Power Cable Con- nections and Switching the Power On/Off” on page E-21.

STANDBY

STANDBY indicator

 

STATUS

AUTO

SOURCE

QUICK

 

MENU

STATUS indicator

MENU

 

 

 

Indicator status

What you should do

 

 

 

 

STATUS

STANDBY When the power is on (Lit green)
It is time to replace the lamp.

 

 

 

Standby (Lit amber)

Replace with a new lamp cartridge.

 

 

 

Lit red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp has reached the end of its service life. The power

STATUS

STANDBY

Blinks amber for 60 seconds, then lit am-

will no longer turn on.

 

 

 

The projector can be used for 100 hours after the lamp has reached

 

 

 

ber

 

 

 

the end of its service life.

 

 

 

Lit red

 

 

 

Replace with a new lamp cartridge.

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

STANDBY

Lit red

The lamp cover is open.

 

 

 

The lamp cover is not properly mounted. Mount it properly.

 

 

 

Blinks red

 

 

 

 

 

 

 

 

(lit for 1 seconds/off for 1 seconds)

 

 

 

 

 

 

 

 

 

 

The temperature is abnormally high.

STATUS

STANDBY

 

• The temperature protector has been activated. If the room tem-

 

perature is high, move the projector to a cool place. If the

 

 

 

Lit red

 

 

 

projector’s internal temperature is high, check the cooling fan’s

 

 

 

 

 

 

 

Blinks red

ventilation slots and clean them if they are clogged.

 

 

 

 

 

 

• When the temperature protector is activated, the power turns

 

 

 

(lit for 0.5 seconds/off for 0.5 seconds)

 

 

 

off and in some cases will not turn back on immediately. In this

 

 

 

 

 

 

 

 

case wait about 90 seconds, then try again.

 

 

 

 

 

STATUS

STANDBY

 

The fan has stopped.

 

 

 

Lit amber

Unplug the power cable and contact a store that sells the U4-232/

 

 

 

Blinks red

U4-232h for repairs.

 

 

 

 

 

 

 

(lit for 0.5 seconds/off for 0.5 seconds)

 

STATUS

STANDBY When the lamp has burned out during use

 

 

 

Blinks amber for 90 seconds, then lit amber

 

 

 

When the lamp does not come on from the start

 

 

 

 

 

 

Lit amber

 

 

 

Blinks red

 

 

 

 

 

 

(lit for 1 seconds/off for 1 seconds)

The lamp will not light.

Wait at least 90 seconds, then turn the power back on. If the problem persists, unplug the power cord and contact a store that sells the U4-232/U4-232h for repairs.

Should an indicator be in a condition other than normal or flash at a rate other than the aforementioned, disconnect the power cable and contact your store of purchase.

Thermal Protector

When the temperature inside the projector becomes abnormally high, the STATUS indicator blinks red (0.5 seconds on/0.5 seconds off), the STANDBY indicator is a steady red, and at the same time the temperature protector operates and switches off the power of the projector.

Should this happen, please take the following actions.

1.Switch off the power and disconnect the power plug from the wall outlet.

2.Check the following matters and take the required measures.

When the projector is being used in a location that has a high ambient temperature, set it up again in a cool location. Check the outflow and intake holes and clean them if they are obstructed.

3.Wait about 60 minutes until the temperature of the projector drops.

If after having performed the above matters, the problem still has not been solved, please contact your store of purchase.

E-55

Page 55
Image 55
PLUS Vision U4-232 When an Indicator is Lit or Blinking, Thermal Protector, E-55, Indicator status, What you should do