English

Quick Installation Instructions

Three quick steps to install and get maximum performance from the Polaris:

• Install the Universal Wall Fitting (UWF) with Quick Disconnect

• Adjust sweep hose to fit pool depth

• Adjust float hose to fit pool length

Install the Universal Wall Fitting

Installs in minutes on pools with a 1-1/2” female threaded return line.

1

1.

Turn on the filtration pump and flush out the plumbing line. Turn pump off.

2.

Polaris 165/Super Turtle Only — Use the return line nearest the center point of the

 

 

longest pool wall for the Polaris. If there are two, choose the return line closest to the pool

 

 

equipment. Place the eyeball regulator disks into the remaining return lines.

 

3.

Remove the UWF from the Quick Disconnect and screw the UWF into the return opening.

 

4.

Turn the Quick Disconnect clockwise into the UWF and pull away to secure.

 

 

1-1/2" return line

 

 

Universal Wall Fitting (UWF)

 

 

Filter Screen

 

 

Quick Disconnect

 

 

Pressure Relief Valve

If the return line has either of the fittings diagrammed below, remove the parts as shown and then install the UWF.

1-1/2” Return Line

1-1/2” Return Line

UWF

UWF

Remove

Remove

Quick

Quick

Disconnect

Disconnect

If the return line is a 1-1/4” or 2” eyeball fitting, order Polaris Adapter Kit (part #6-510-00) from an authorized Polaris dealer. If the return line differs from all of these, contact Polaris for assistance.