Chapter 1- Hardware Description

Table 1-9RMX™ 4000 Slot Numbering

Slot ID/No.

Card/Component

Requirement

 

 

 

12

Fan Drawer

Mandatory

 

 

 

13-16

RTM ISDN/RTM

Either an RTM ISDN or an RTM LAN

 

LAN

card is mandatory in combination with a

 

 

Media card. The RTM ISDN/RTM LAN

 

 

board must be inserted in a slot opposite

 

 

any MPM+ card.

 

 

 

17

RTM-IP 4000

Mandatory

 

 

 

18

Blank Panel

Not Available (NA)

 

 

 

19-21

Power Modules

Mandatory:

 

 

With AC power, 3 power supplies are

 

 

installed, with the 3rd redundant.

 

 

With DC power, 2 power supplies are

 

 

installed with the 2nd redundant. The

 

 

center slot (#20) on the rear of the RMX

 

 

4000 is disabled and is fitted with blank

 

 

panel.

 

 

Note: Protective bonding conductor size

 

 

is 14AWG (1.5mm) within the Power

 

 

Entry Model.

 

 

 

1-30

Page 36
Image 36
Polycom DOC2548A manual Rtm Isdn/Rtm