Chapter 2- Component Replacement

2Power down the card by partially opening the ejector levers until the blue HS LED on the card and the Control Unit start to flash.

Warning!

Once the removal sequence is initiated the process cannot be terminated and the HS LED flashes.

3The power off sequence for the interconnected MPM+ and RTM ISDN cards are initiated as follows:

All participant connections on the card are disconnected.

A fault is generated on the system.

For each disconnected participant, a participant disconnection event is written to the CDR with the disconnection cause Disconnected by Operator.

New participant connections are blocked when the card is removed.

If an RTM ISDN card is connected to the MPM+ card it is also powered off and all ISDN and PSTN participants are disconnected.

When an RTM ISDN card is removed, its resources are deducted from the Resource Report.

A Log File entry is written indicating MPM+ card removal.

Port usage is re-calculated and the Port Gauges and Video/Voice Port Configuration dialog box are updated.

4When the blue HS LEDs on the MPM+, RTM ISDN and Control Unit stop flashing and remain lit, unscrew the captive screws and move the ejector levers to their fully open position and remove the MPM+ card.

2-12

Page 54
Image 54
Polycom DOC2548A manual Component Replacement