Polycom MX392 manual

Models: MX392

1 44
Download 44 pages 56.9 Kb
Page 27
Image 27
Manual background

Now, right click in the HELD COMMAND column for Logic Input 1 and select INSERT, INPUT, 1, MUTE, OFF. Now, whenever the switch goes Active Low (0V DC), the Vortex Device will unmute Input 1.

If you are successful, you should see this on the screen:

Make sure that the physical wiring works by pressing and holding the membrane switch. You should see the LED above the pin assignment lit in green:

Repeat the above process for each MX392 microphone that you want to connect to the Vortex Device.

27

Page 27
Image 27
Polycom MX392 manual