microphones on all units regardless of whether a microphone is muted from the Vortex EF2280 or the Vortex EF2241. To accomplish this, we will use the BROADA command to send MUTEI commands from one unit to the other unit. The BROADA command broadcasts any command that is after the colon. For example, if a Macro in the Vortex EF2241 has this command:

BROADA:F00MUTEI11

then when this Macro is executed, the microphone that is connected to EF2280 ID 00 will be muted.

In order to do this, let's look at the Macros page of the Vortex EF2280. Left-click on Item 8 in Macro 0. Then click the INSERT button to add a ninth command to Macro 0. At this point, place the cursor in the COMMAND column and type:

BROADA:B01MUTEI11

Repeat that same process for Inputs 2-4 of the EF2241. The, perform the same procedure to unmute Inputs 1-4 on the EF2241. Remember that there is a colon after the BROADA command. When you are finished, here is what the Macros page should look like: