BREAK-IN PROCEDURES

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service. (before the hose is installed), the check valve is replaced, or a complete compressor pump is replaced.

The procedure:

1.Make sure the pressure switch lever is in the "OFF" position.

2.Plug the power cord into the correct branch circuit receptacle.

3.Open the drain valve fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the pressure switch lever to "ON/AUTO". The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve.

7.Move the pressure switch lever to "ON/AUTO". The air receiver will fill to cut- out pressure and the motor will stop. The compressor is now ready for use.

OPERATING PROCEDURES

Daily Start-Up Checklist

1.Before attaching air hose or accessories, make sure the ON/AUTO lever is set to “OFF” and the air regulator is closed.

2.Attach hose and accessories.

TOO MUCH AIR PRESSURE CAUSES A HAZARDOUS RISK OF BURSTING. CHECK THE MANUFACTURER'S MAXIMUM PRESSURE RATING FOR AIR TOOLS AND ACCESSORIES. THE REGULATOR OUTLET PRESSURE MUST NEVER EXCEED THE MAXIMUM PRESSURE RATING.

3.Turn the ON/AUTO lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.

4.Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. Your compressor is ready for use.

5.Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressoris being used to operate a sprayer DO NOT use near the spray area.

When you are finished:

6.Set the “ON/AUTO” lever to “OFF”.

7.Turn the regulator counterclockwise and set the outlet pressure to zero.

8.Remove the air tool or accessory.

9.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

10.Drain water from air tank by opening drain cock valve on bottom of tank.

WATER WILL CONDENSE IN THE AIR TANK. IF NOT DRAINED, WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE.

11.After the water has been drained, close the drain cock or drain valve. The air compressor can now be stored.

NOTE

If drain cock valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

10-ENG

Page 10
Image 10
Porter-Cable CPFC2TV3525VP instruction manual BREAK-IN Procedures, Operating Procedures, Daily Start-Up Checklist