Porter-Cable D20498 Maintenance, Customer Responsibilities Table, General Recommendations

Models: 919.329150 D20498

1 44
Download 44 pages 57 Kb
Page 16
Image 16

MAINTENANCE

CUSTOMER RESPONSIBILITIES TABLE

Before each

Every 25

Every 50

Every 100

use

Hours of Every

Hours of Every

Hours of Every

 

Season

Season

Season

MAINTENANCE TASK

 

 

 

 

 

 

 

Check oil level

X

See Note 2

 

Change oil

 

 

See Note 1

 

 

 

 

Clean Air Filter Assembly

 

X

 

 

 

 

Check Spark Plug

 

X

X

Prepare Unit for Storage

Prepare unit for storage if it is to remain idle for more than 30 days.

Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extreme dusty or dirty conditions.

Note 2: Check oil after 5 hours of operation (See the Oil paragraph on page 15 of this section)

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to operator abuse or negli- gence. To receive full value from the warranty, opera- tor must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to maintain your generator.

GENERATOR MAINTENANCE

Your generator should be kept clean and dry at all times. The generator should not be stored or oper- ated in environments that include excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the generator head.

All adjustments in the Maintenance section of this manual should be made at least once each season.

ENGINE MAINTENANCE

NOTICE: Maintenance, replacement or repair of the emission control devices and systems may be performed by any nonroad engine repair establishment or individual. However, to obtain no charge repairs under the terms and provisions of the engine manufacturers warranty statement, any service or emission control part repair or replacement must be performed by a factory authorized dealer.

Oil

Oil level should be checked prior to each use and at least every 5 hours of operation. To check oil see Adding Engine Oil paragraph in the Operation section on page 14.

Changing Engine Oil

For a new engine, change oil after the first 2 operating hours. Thereafter, change oil after every 50 hours of operation.

Change the oil while the engine is still warm. The oil will flow freely and carry away more impurities. Make sure the engine is level when filling, checking or changing oil.

Change the oil as follows:

To keep dirt, grass clippings, etc. out of the engine, clean the area around the drain plug and dipstickbefore removing it.

Remove the oil drain plug and dipstick. Tilt the engine slightly towards the oil drain to obtain better drainage. Be sure to allow ample time for complete drainage.

D20498 Rev. 0 6/9/00

16 — ENG

Page 16
Image 16