Porter-Cable D26126-024-0 Maintenance, Customer Responsibilities, To Check Safety Valve

Models: D26126-024-0

1 18
Download 18 pages 55.69 Kb
Page 14
Image 14

MAINTENANCE

Customer Responsibilities

 

Before

Daily or

 

each

after

 

each

 

use

 

use

 

 

Check Safety Valve

 

Drain Tank

 

Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage

sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work properly, over- pressurization may occur, causing air tank rupture or an

explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to "OFF".

2.Pull the regulator knob out and turn counter-clockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air

tank rupture.

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

D26126

14 - ENG

Page 14
Image 14
Porter-Cable D26126-024-0 instruction manual Maintenance, Customer Responsibilities, To Check Safety Valve, To Drain Tank