Porter-Cable D26126-024-0 instruction manual To Replace Regulator

Models: D26126-024-0

1 18
Download 18 pages 55.69 Kb
Page 16
Image 16

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.

Unplug unit.

 

 

 

Outlet

 

 

 

 

Pressure

 

 

 

 

 

 

 

3.

Using an adjustable wrench remove the

 

 

 

Gauge

 

 

outlet pressure gauge and quick connect

 

 

 

 

 

 

from the regulator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quick

 

 

 

 

Regulator

 

 

 

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Remove the regulator.

5.Apply pipe sealant tape to the nipple on the standpipe.

6.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to outlet pressure gauge and quick connect.

8.Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten connect with wrench.

Nipple

Regulator

Regulator

Arrow

D26126

16 - ENG

Page 16
Image 16