BEFORE START UP
This generator has been shipped from the fac- tory without oil in the crankcase. Operating the unit without oil can damage the engine.
Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine.
Follow the steps listed below before starting gener- ator:
1.Check engine oil. Refer to the Engine Operator's Manual for correct grade and quantity of oil.
2.Check fuel level, fill as required. Make sure genera- tor is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline.
Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting en- gine.
Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.
Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains car- bon monoxide, an odorless and deadly gas.
3.Make sure generator is grounded in accordance with local requirements.
4.All electrical loads MUST be disconnected
Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire. Never attempt to
You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.
12 — ENG