Powercom 3000AL, 800A, 2000AL, 3000A &1000AL, 1500A, ls600A, 2500A Net Weight 18.0 23.5 26.1 28.4

Models: ls600A 2000AL 2500A 3000A &1000AL 1000A 1500A 1250A 2000A 800A 3000AL

1 20
Download 20 pages 30.3 Kb
Page 18
Image 18

 

Protection

Automatic self-test & discharge protection, Replace battery indicator

 

 

 

 

 

 

 

 

 

 

 

Back - up Time

 

10 - 30 minutes (depending on computer load)

 

PHYSICAL

Net Weight

18.0

23.5

 

26.1

28.4

 

55.2

 

57.8

 

Kg(lbs)

(39.6)

(51.7)

 

(57.4)

(62.4)

 

(121.4)

 

(127.1)

 

Shipping Weight

19.5

25.0

 

27.7

30.0

 

58.0

 

60.0

 

Kg(lbs)

(42.9)

(55.0)

 

(60.9)

(66.0)

 

(127.6)

 

(132.0)

 

Dimension(mm)

 

483 x 381 x 130

 

 

 

483 x 508 x 221

 

WxDxH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Inlet

 

 

 

IEC 320 power inlet

 

 

 

 

Receptacles

NEMA 5-15R (115V)/IEC 320 female appliance coupler (230V)

 

 

 

 

 

 

ALARM

Battery

 

Slow beeping sound (about 0.25Hz)

 

 

Back-Up

 

 

 

 

 

 

 

 

 

 

 

Battery Low

 

Rapid beeping sound (about 1.00Hz)

 

 

Overload

 

 

 

Continue beeping sound

 

INTERFACE

Support both

Provide power management & diagnostic functions including power

 

RS232 &dry

status, battery low, schedule UPS ON/OFF, battery/load level display

 

contact signal

and more. Compatible with Windows 95/98/NT, Novell, Unix and other

 

 

 

 

 

popular systems.

 

 

 

 

 

 

 

ENVIRONMENT

Ambient

3,500 meters max. elevation, 0-95% humidity non-condensing

 

operation

 

 

 

0-40 deg C

 

 

 

 

Audible noise

<40dBA (1 meter from surface)

 

<45dBA (1 meter from surface)

 

Storage

 

 

15000 meters

max. elevation

 

 

condition

 

 

 

 

 

 

 

 

 

 

14. Specifications

MODEL

 

SMK

 

SMK

 

SMK

SMK

 

SMK

 

 

2500A

 

3000A

 

1000AL

2000AL

 

3000AL

INPUT

Capacity

2500VA

 

3000VA

 

1000VA

2000VA

 

3000VA

 

Voltage

 

 

+/-25% at line input, Single

phase

 

 

Frequency

 

 

50 or 60Hz +/-5% (auto sensing)

 

OUTPUT

Voltage

Pure sine wave at +/-5% of nominal, -10% after low battery

 

(on battery)

 

 

 

warning

 

 

 

 

Frequency

 

 

50 or 60Hz +/-0.5%

 

 

 

 

(on battery)

 

 

 

 

 

 

 

 

 

Voltage

AVR automatically increase output voltage 15% above input

 

Regulation

voltage if -9% to-25% of nominal. AVR decrease output voltage

 

AVR

15% below input voltage if+9% to +25% of nominal

 

 

 

 

 

 

 

 

PROTECTION

Surge

 

 

320 Joules, 2ms

 

 

 

AND

Protection

 

 

 

 

 

 

 

 

FILTERING

 

 

 

 

 

 

 

 

 

Unit Input

 

Breaker for overload & short circuit protection

 

 

 

 

 

 

 

 

 

 

 

EMI/RFI filter

 

 

10dB at 0.15MHz, 50dB at 30MHz

 

 

Overload

UPS automatic shutdown if overload exceeds 110% of nominal at

 

Protection

 

 

20 second and 125% at 2 seconds.

 

 

 

 

 

 

 

 

Transfer Time

 

 

2/4 milliseconds, including detection time

 

 

Short Circuit

UPS output cut off immediately or input fuse protection

BATTERY

Type

Hot swappable, Sealed, Maintenance-free lead acid ,with 3-6

 

 

 

 

years life time

 

 

 

 

Typical

 

 

4 hours (to 90% of full capacity)

 

 

Recharge Time

 

 

 

 

 

 

 

 

Page 18
Image 18
Powercom 3000AL, 800A, 2000AL, 3000A &1000AL, 1500A, ls600A, 2500A, 1250A user manual Net Weight 18.0 23.5 26.1 28.4