Protection

Automatic self-test & discharge protection, Replace battery

 

 

 

 

 

 

indicator

 

 

 

 

Back - up Time

 

10 - 30 minutes (depending on computer load)

 

PHYSICAL

Net Weight

13.8

 

14.5

 

15

 

15.8

 

25

 

30

 

Kg(lbs)

(30.4)

 

(31.9)

 

(33.0)

 

(34.8)

 

(55.0)

 

(66.0)

 

Shipping Weight

14.8

 

15.5

 

16

 

16.8

 

27

 

32

 

Kg(lbs)

(32.6)

 

(34.1)

 

(35.2)

 

(37.0)

 

(59.4)

 

(70.4)

 

Dimension(mm)

140x445x200

 

140x445x200

 

170x450x215

 

WxDxH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Inlet

 

 

 

 

IEC 320 power inlet

 

 

 

 

 

Receptacles

NEMA 5-15R (115V)/IEC 320 female appliance coupler (230V)

 

 

 

 

 

 

 

ALARM

Battery

 

 

Slow beeping sound (about 0.25Hz)

 

 

Back-Up

 

 

 

 

 

 

 

 

 

 

 

 

Battery Low

 

 

Rapid beeping sound (about 1.00Hz)

 

 

Overload

 

 

 

Continue beeping sound

 

 

 

INTERFACE

RS-232

 

 

Bi-directional communication port

 

 

I t f

 

 

 

 

 

 

 

 

 

 

 

CONFORMANCE

Safety

 

 

 

cUL, TUV, CE, meet FCC

 

 

 

 

Surge

 

 

 

Meet IEEE 587 standard

 

 

 

 

Warranty

 

 

 

 

Two years

 

 

 

 

 

 

 

ENVIRONMENT

Ambient

6,000 meters max. elevation, 0-95% humidity non-condensing

 

operation

 

 

 

 

0-40 deg C

 

 

 

 

Audible noise

<40dBA (1 meter from surface)

<45dBA (1 meter from surface)

 

Storage

 

 

15000 meters

max. elevation

 

 

 

 

condition

 

 

 

 

 

 

 

 

 

 

 

14. Specifications

MODEL

 

SMK

SMK

SMK

SMK

SMK

SMK

 

 

800A RM

1250A RM

1500A RM

2000A RM

2500A RM

3000A RM

INPUT

Capacity

800VA

1250VA

1500VA

2000VA

2500VA

3000VA

 

Voltage

 

+/-25% at line input , Single phase

 

 

Frequency

 

50 or 60Hz +/-5% (auto sensing)

 

OUTPUT

Voltage

Pure sine wave output at +/-5% of nominal, -10% after low battery

 

(on battery)

 

 

warning

 

 

 

Frequency

 

 

50 or 60Hz +/-0.5%

 

 

 

(on battery)

 

 

 

 

 

 

 

Voltage

AVR automatically increase output voltage 15% above input voltage if

 

Regulation

-9% to-25% of nominal. AVR decrease output voltage 15% below input

 

AVR

 

voltage if+9% to +25% of nominal

 

 

 

 

 

 

 

 

PROTECTION

Spike Protection

 

 

320 Joules, 2ms

 

 

AND

Unit Input

 

Fuse for overload & short circuit protection

 

FILTERING

 

 

 

 

 

 

 

EMI/RFI filter

 

10dB at 0.15MHz, 50dB at 30MHz

 

 

 

 

 

Overload

UPS automatic shutdown if overload exceeds 110% of nominal at 20

 

Protection

 

second and 125% at 2 seconds.

 

 

 

 

 

 

 

Transfer Time

 

2/4 milliseconds, including detection time

 

 

Short Circuit

UPS output cut off immediately or input fuse / breaker protection

BATTERY

Type

Hot swappable, Sealed, Maintenance-free lead acid , with 3-6 years

 

 

 

 

lifetime

 

 

 

Typical

 

4 hours (to 90% of full capacity)

 

 

Recharge Time

 

 

 

 

 

 

Page 17