Table 3-1: Troubleshooting Steps
Symptom Corrective Steps
The end device
operates, but
there is no data
link.
1. Verify that the port indicator on the front panel is
continuously lit.
2. If an external power splitter is in use, replace it with a
known-good splitter.
3. Verify that for this link, you are using standard
UTP/FTP Category 5 straight (non-crossover)
cabling, with all four pairs. Check that the link is 100
m or less.
4. Try to re-connect the same end device into a different
port on the same unit or into different unit if it works,
there is probably a faulty port or RJ-45 connection.
Is it safe to keep
the Midspan
running while a
port indicator is
orange?
This is a safe condition. The orange indication is due to:
1.
A device, not compliant to IEEE 802.3af, was detected.
2. Terminals 4/5 and 7/8 are shorted together.
3. Forced external power fed into the port.
During these conditions, port power is disconnected.
Technical Specifications
Physical Specifications
Dimensions 44 x 281 x 248 mm
(h x w x l) (1.73 x 11.06 x 9.76 inch)
Weight 1.2 kg (3.2 lb)
Environmental Specifications
Temperature
- Operating 0 to 40 °C (32 to 104 °F)
- Storage -20 to 70 °C (-4 to 158 °F)
Humidity 10 to 90% (non-condensing)
Electrical Specifications
Input Voltage 90 to 264 VAC at 47-63 Hz
Input Current 1.5 A max. at 115 Vac
Total Output Power 92 W max.
Output Power, per Port 15.4 W (not to exceed 92 W total for all ports)
Nominal Output Voltage 44 to 57 VDC