PD-6006/12/24
Power over LAN Solutions 5 Cat. No.: 06-6800-056
1 Safety Information

1.1 General Guidelines

You must read the following safety information before carrying out any
installation, removal or any maintenance procedure on the Power over LAN
Midspan. Warnings contain directions that must be followed for personal and
product safety. Follow all directions carefully.
WARNINGS
Read the Installation Instructions in Section 3 before connecting the
Power over LAN Midspan to its power source.
The Midspan must use a grounded power cord, as defined in
paragraph 1.2.
This product relies on the building installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no larger
than 15 A for 120 VAC, (U.S.) 10 A for 230 VAC (international) is
used.
Do not work on the system, connect or disconnect cables during
periods of lightning activity.
A voltage mismatch can cause equipment damage and may pose a
fire hazard. If the voltage indicated on the label is different from the
power outlet voltage, do not connect the Power over LAN Midspan to
this outlet.
For shelf-mounted equipment, be certain that the surface is stable and
strong enough to support the equipment. Do not stack more than four
the Power over LAN Midspans.
Ultimate disposal of this product should be handled according to all
local laws and regulations.
The Power over LAN Midspan "Data" and "Data + Power" ports are
shielded RJ-45 data sockets. They cannot be used as Plain Old
Telephone Service (POTS) telephone sockets. Only RJ-45 data
connectors may be connected to these sockets.