PD-6006/12/24

2.3.2Port Indications

One bi-color indicator (green and orange), per port, provides port status:

Green indicates that the terminal unit has been identified as "Power over LAN Enabled" and is active and receiving power. Orange indicates that the port is not supplying power and is not active.

Refer to Table 2-2 for additional information.

Note Due to the standard detection process performed on each PoL port, power will not be supplied to an Ethernet device, that is not PoL-enabled (indicated in orange or off). In this way, Ethernet devices (not PoL-enabled) will not be affected by this connection.

Table 2-1: Power Status Indications

Indicator

Color

Main Power

Remarks

Status

 

 

 

 

 

 

Internal power

Internal power supply voltage

 

Off

supply unit is

is too low. All ports are

 

unplugged or

disconnected.

 

 

 

 

faulty.

 

 

 

 

 

 

AC

 

Indicates AC

Internal power supply voltage

Green

power input

is within tolerance.

 

 

 

active.

 

 

 

 

 

 

 

Green

Internal power

All ports are disconnected.

 

supply voltage is

 

 

 

blinking

 

 

 

out of tolerance.

 

 

 

 

 

 

 

 

 

 

 

Off

No DC input

DC input voltage is too low.

 

power available.

All ports are disconnected.

 

 

DC

 

Indicates DC

DC input voltage is within

Green

power input

tolerance.

 

 

active.

 

 

 

 

 

 

 

Green

DC Input voltage

All ports are disconnected.

 

blinking

is out of tolerance.

 

 

 

 

 

 

AC and DC

Orange

Internal problem

Built in Test (BIT) failed.

alarm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power over LAN Solutions

9

Cat. No.: 06-6800-056

Page 9
Image 9