TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | CORRECTIVE ACTION | |
|
|
| |
Low generator output | Excitation capacitor failure | • Contact a qualified generator dealer for service assistance. | |
|
| ||
voltage | Generator diode or varistor | • Contact a qualified generator dealer for service assistance. | |
| failure | ||
|
| ||
Overspeed light stays lit | Shutdown due to high engine | • Verify correct engine speed setting. | |
speed | |||
Underspeed light stays | Shutdown due to low engine | • Reduce loads connected to generator. | |
lit | speed | ||
| |||
Overcrank light stays lit | Failure to start | • See "Engine cranks without starting". | |
|
|
| |
Not In Auto light stays lit | Generator not set for | • Place mode switch into AUTO position if automatic | |
unattended operation | function is required. | ||
Low oil pressure light | Shutdown due to low engine | • Check engine oil level. | |
| |||
stays lit | oil pressure | • Verify correct type of engine oil for ambient temperature | |
|
| conditions. | |
|
| • Test battery. Replace as necessary. | |
|
|
| |
|
| • Ensure charger is plugged into receptacle. | |
|
|
| |
Low battery light stays lit | Low battery | • Check for tripped main circuit breaker. Reset if required. | |
| |||
• Check all charger cable connections for cleanness and | |||
|
| ||
|
| tightness. | |
|
| • Check battery charger inline fuse. | |
|
|
| |
|
| • Check charger lights to verify correct operation. See Table | |
|
| A, Page 25. | |
|
| • Allow engine to cool, then restart. | |
|
|
| |
High engine temperature | Shutdown due to high engine | • Decrease loads on generator. | |
light stays lit | temperature | • Check enclosure openings for blockage. | |
|
| ||
|
|
| |
|
| • Check radiator coolant level. | |
|
|
|
28 |