GENERATOR SPECIFICATIONS
| P2201 (22 KW) | P2701 (27 KW) | P3201 (32 KW) | |
|
|
|
| |
Rated Wattage - (Standby) | 22,000 | 27,000 | 32,000 | |
@1.0 PF LPG * | ||||
|
|
| ||
Rated Wattage - (Standby) | 19,800 | 24,300 | 28,800 | |
@1.0 PF NG * | ||||
|
|
| ||
Voltage | 120/240 volts | 120/240 volts | 120/240 volts | |
Rated Current | 184/92 amps LPG | 224/112 amps LPG | 255/133 amps LPG | |
Frequency | 60 HZ | 60 HZ | 60 HZ | |
Power Factor | 1.0 | 1.0 | 1.0 | |
Max. Ambient Temp Rise | 105°C | 105°C | 105°C | |
Insulation class | H | H | H | |
Engine | GM 3.0 L | GM 3.0 L | GM 3.0 L | |
Engine Type | Water cooled inline (4 cyliners) | Water cooled inline (4 cyliners) | Water cooled inline (4 cyliners) | |
|
|
|
| |
RPM | 1800 | 1800 | 1800 | |
Displacement cc (c.i.d) | 2966 (181) | 2966 (181) | 2966 (181) | |
Bore X Stroke mm (inches) | 101.60 x 91.44 (4.00 x 3.60) | 101.60 x 91.44 (4.00 x 3.60) | 101.60 x 91.44 (4.00 x 3.60) | |
Compression Ratio | 10:5:1 | 10:5:1 | 10:5:1 | |
Valve arrangement | Overhead valve | Overhead valve | Overhead valve | |
Governor | Electronic, Isochronous | Electronic, Isochronous | Electronic, Isochronous | |
Ignition system | Solid State Distributor | Solid State Distributor | Solid State Distributor | |
Starter | 12vdc, Solenoid Shift | 12vdc, Solenoid Shift | 12vdc, Solenoid Shift | |
Alternator | 12vdc | 12vdc | 12vdc | |
Oil Capacity (w/o filter) | 4 qts (3.8L) | 4 qts (3.8L) | 4 qts (3.8L) | |
Oil Capacity (with filter) | 5 qts (4.7L) | 5 qts (4.7L) | 5 qts (4.7L) | |
Oil Filter | ||||
Radiator capacity | Shipped with 50/50 mix of | Shipped with 50/50 mix of | Shipped with 50/50 mix of | |
water and propylene glycol | water and propylene glycol | water and propylene glycol | ||
| antifreeze. | antifreeze. | antifreeze. | |
Spark plug | AC Delco R45TS | AC Delco R45TS | AC Delco R45TS | |
Battery | BCI Group 34, minimum | BCI Group 34, minimum | BCI Group 34, minimum 750 | |
750 CCA | 750 CCA | CCA | ||
| ||||
Air filter | ||||
Minimum Content |
|
|
| |
Requirements for Natural Gas | 1000 BTU’s per cubic foot | 1000 BTU’sper cubic foot | 1000 BTU’sper cubic foot | |
(NG) ** |
|
|
| |
Minimum Content |
|
|
| |
Requirements for Liquid | 2520 BTU’sper cubic foot | 2520 BTU’sper cubic foot | 2520 BTU’s per cubic foot | |
Propane Vapor (LPG) ** |
|
|
| |
Consumption at Full Load for | 280 cubic feet per hour | 304 cubic feet per hour | 315 cubic feet per hour | |
Natural Gas (NG) | ||||
|
|
| ||
Consumption at Full Load for | 3.44 gallons per hour | 3.71 gallons per hour | 3.99 gallons per hour | |
Liquid Propane Vapor (LPG) | ||||
|
|
| ||
Dimensions (see next page | 66”L x 35”W x 41”H | 66”L x 35”W x 41”H | 66”L x 35”W x 41”H | |
for installation drawing) | ||||
|
|
| ||
Shipping Weight | 1300 | 1300 | 1300 | |
Normal Operating Range |
|
|
* Note: Rated wattage is specified at sea level, 60°F ambient temperature, and propane fuel (with 2500 BTU/cuft). Rated wattage decreases approximately 3.5% for each 1000ft above sea level and approximately 1% for each 10°F above 60°F ambient temperature.
** Fuel supply pressures must be between 4 oz (6” w.c.) and 6 oz (11” w.c.) at inlet to the unit.
6 |