MAJOR GENERATOR FEATURES

*25 HP Subaru OHV engine

*Cast-iron cylinder sleeve

*Low oil sensor

*Receptacles on control panel

*Electric Start

*Idle control

*CordKeeper™

*8 gallon plastic fuel tank

*Spark arrester

*Portability Kit

CONTROL PANEL

A.120 Volt GFCI Receptacle

Ground Fault Circuit Interrupter duplex receptacle is rated

so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings.

Ground Fault Circuit Interrupter

(Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical

shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc.

The GFCI receptacle cannot be reset once tripped, unless the generator is running and power is available to it. Test regularly to assure proper operation.

B.120 Volt, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps from this

receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.

C.120/240 Volt Heavy Duty Receptacle

This receptacle is rated at 50 amps but the current must be

limited to the nameplate rating. If this receptacle is used along with the 120 volt receptacles, the total load drawn must not exceed the nameplate ratings.

D.Circuit Breakers

The receptacles are protected by an AC circuit breaker. If

the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE:

Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

E.Idle Control Switch

The Idle Control circuit is designed to extend engine life

and improve fuel usage by slowing the engine down to approximately 2000 RPM in a “No Load” condition. The noise is also greatly reduced during this condition.

When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition. Likewise, when the load is removed, the generator will automatically return to the idle condition after a 4-5 second delay.

A convenient switch is mounted in the control panel for easy access and will disable the Idle Control circuitry when in the off position.

NOTE: A 12V battery must be installed in order for the idle control to function.

F.CordKeeper™ Restraint

The CordKeeper™ restraint is a unique

feature used to prevent plugs from being pulled out of the receptacles.

POWER CORD CONNECTIONS

Refer to the appropriate diagram for proper connection of power cord wires to the plug terminals.

CAUTION: Insure that the power cord used is well insulated and has a sufficient rating to match that of the plug.

120 Volt 30 Amp Plug

120/240 Volt Heavy Duty Plug

 

 

English

2

 

 

Page 2
Image 2
Powermate PM0601350 manual Major Generator Features, Control Panel, Power Cord Connections

PM0601350 specifications

The Powermate PM0601350 is a versatile and reliable portable generator designed to meet the power needs of both residential and commercial applications. With its robust construction and advanced features, this generator has become a go-to solution for backup power and outdoor activities.

One of the standout features of the PM0601350 is its impressive power output. It boasts a maximum output of 6,500 watts, making it suitable for running multiple appliances and tools simultaneously. The generator is equipped with a 13 HP OHV engine, which provides reliable and efficient performance. The engine's overhead valve design enhances fuel efficiency while reducing emissions, making it an environmentally friendly option.

The PM0601350 also incorporates several technologies that enhance its usability and performance. One such feature is the electric start system, which provides the convenience of starting the generator with just the push of a button. This eliminates the hassle of manual recoil starting, especially in challenging conditions. Additionally, the generator includes a low oil shutdown system that automatically turns off the engine when oil levels drop too low, preventing potential damage and extending the life of the generator.

Portability is another key characteristic of the Powermate PM0601350. It features a sturdy, compact design fitted with heavy-duty wheels and a foldable handle, allowing for easy transportation across various terrains. This makes it ideal for camping trips, tailgating, or as a power source for outdoor events.

For user convenience, the PM0601350 offers multiple outlet options, including 120V household outlets and 12V DC ports. This versatility allows users to connect a wide range of devices, from household appliances to power tools, without the need for additional adapters. The generator also features a large fuel tank, providing an extended runtime that ensures power availability during lengthy outages or outdoor excursions.

In terms of safety, the generator is equipped with circuit breakers to protect against overloads, ensuring a safe operation.

Overall, the Powermate PM0601350 is a powerful and efficient portable generator that combines advanced technology with practical features, making it an excellent choice for anyone in need of reliable backup power or a portable energy source for various activities. Its combination of performance, ease of use, and safety makes it a valuable addition to any toolkit.