Page 2 of 4
PM4025
25kW
Gaseous Fueled Stationary Standby | 60Hz |
Engine Data |
|
General |
|
Manufacturer | Ford |
Model | |
Type | |
Horsepower | 45 Maximum (LP)@ 1800rpm |
Cylinder Block Material | Cast Iron |
Cylinders | 4 |
Aspiration | Natural |
Air Cleaner | Heavy Duty Replaceable Dry Element |
Displacement | 2.5 Liters |
Compression Ratio | 9.37:1 |
Bore | 96mm |
Stroke | 86.3mm |
RPM | 1800 |
Engine Governing | ± 0.5% - Electronic |
Fuel System |
|
Fuel System | Woodward Fuel Mixer, Secondary Regulator, 12vdc Positive Locking |
Fuel Type | Liquefied Petroleum Gas(Vapor) Or Natural Gas |
Injection Method | Carburetor Induction |
Lubrication System |
|
Lube Oil System | Centrifugal Pump, |
Lube Oil Capacity | 4.5 Quarts W/Filter |
Cooling System |
|
Cooling System | 105°F Ambient Radiator Equipped |
Ambient Operating Temperature Range | |
Cooling System Capacity | 2.8 Gallons |
Coolant Flow Rate | 17.4 GPM |
Coolant Heater | 120v, 500 Watt Thermostatically Controlled Circulation Type |
Electrical |
|
Starting Voltage | 12v negative ground |
Battery Size Required | BCI Group 26, Battery Rack & 2/0 Cables Included |
Cranking Current | 550cca @ 0°F |
Battery Charging Alternator | 90 amps |
Battery Charger (120v AC) | Bulk - 6A, 12vdc |
| Absorption - 5.5A, Taper To 1.5A Between |
| Float – 0.1 To 0.3A, 13.3vdc Κ 0.3vdc |
Engine Emission Data |
|
Permits: |
|
California Air Resource Board | Consult Factory |
South Coast Air Quality Management | Consult Factory |
District |
|
Emissions Data* Tested To ISO 8178 D2 Cycle: |
|
Hydrocarbons | Consult Factory |
Nitric Oxide | Consult Factory |
Carbon Monoxide | Consult Factory |
Particulate Matter | Consult Factory |
*Emission levels may rise above published limits due to improper maintenance or altered air intake/airflow.
All Specifications Subject to Change Without Notice | ©2002 Coleman Powermate, Inc. |
| Coleman® is a registered trademark of the Coleman Company, Inc. used under license. |