Page 3 of 4
PM4025
Gaseous Fueled Stationary Standby
Fuel System
Fuel Type
Fuel Supply Inlet
Fuel Supply Pressure
25kW
60Hz
Liquefied Petroleum Gas Vapor or Natural Gas (LP Liquid Optional) 1/2” NPT
Fuel Consumption
Fuel Consumption @ % Load | LP Gas (Cubic Feet/Hour) | Natural Gas (Cubic Feet/Hour) |
25% | 34 | 85 |
50% | 67 | 169 |
75% | 101 | 254 |
100% | 135 | 304 |
Engine Generator Application/Installation Data
Radiator Airflow | 4200 | CFM |
Alternator Airflow | 250 CFM | |
Combustion Airflow | 100 CFM | |
Total Airflow | 4550 | CFM |
Heat Rejected To Coolant | 70000 BTU/HR | |
Heat Rejected To Exhaust | 195000 BTU/HR | |
Maximum Exhaust Flow | 206 CFM | |
Maximum Exhaust Backpressure | 1.1 PSI | |
Exhaust Temperature | 1200 | °F |
Sound Data
66 dB(A) Average @ 23’ (7m) @ Full Load
23 Feet (7m) 10 Feet (3m)
Position | 50% Load | 100% Load |
A | 74.5 | 77 |
B | 69 | 70.5 |
C | 73 | 74 |
D | 71 | 72.5 |
Average |
|
|
72 | 74 | |
| ||
Position | 50% Load | 100% Load |
A | 66 | 67 |
B | 64.5 | 65.5 |
C | 65.5 | 67 |
D | 65 | 66 |
Average |
|
|
65 | 66 | |
|
|
|
©2002 Coleman Powermate, Inc. Coleman® is a registered trademark of the Coleman Company, Inc. used under license.
All Specifications Subject to Change Without Notice