Powermate PM4025 warranty Fuel System, 25kW 60Hz, Sound Data, Fuel Consumption @ % Load

Models: PM4025

1 4
Download 4 pages 46.98 Kb
Page 3
Image 3
Fuel System

Page 3 of 4

PM4025

Gaseous Fueled Stationary Standby

Fuel System

Fuel Type

Fuel Supply Inlet

Fuel Supply Pressure

25kW

60Hz

Liquefied Petroleum Gas Vapor or Natural Gas (LP Liquid Optional) 1/2” NPT

7-11 (In/H2O)

4-6 (Oz/In2)

Fuel Consumption

Fuel Consumption @ % Load

LP Gas (Cubic Feet/Hour)

Natural Gas (Cubic Feet/Hour)

25%

34

85

50%

67

169

75%

101

254

100%

135

304

Engine Generator Application/Installation Data

Radiator Airflow

4200

CFM

Alternator Airflow

250 CFM

Combustion Airflow

100 CFM

Total Airflow

4550

CFM

Heat Rejected To Coolant

70000 BTU/HR

Heat Rejected To Exhaust

195000 BTU/HR

Maximum Exhaust Flow

206 CFM

Maximum Exhaust Backpressure

1.1 PSI

Exhaust Temperature

1200

°F

Sound Data

66 dB(A) Average @ 23’ (7m) @ Full Load

25kW23 Feet (7m) 10 Feet (3m)Fuel Consumption

Position

50% Load

100% Load

A

74.5

77

B

69

70.5

C

73

74

D

71

72.5

Average

 

 

72

74

 

Position

50% Load

100% Load

A

66

67

B

64.5

65.5

C

65.5

67

D

65

66

Average

 

 

65

66

 

 

 

©2002 Coleman Powermate, Inc. Coleman® is a registered trademark of the Coleman Company, Inc. used under license.

All Specifications Subject to Change Without Notice

Page 3
Image 3
Powermate PM4025 Fuel System, 25kW 60Hz, Fuel Consumption, Engine Generator Application/Installation Data, Sound Data