Trouble
Machine will not start/restart or repeatedly trips circuit breaker or blows fuses.
(cont.)
Probable Cause | Remedy | |
|
| |
| Examine motor starter for burned or | |
| failed components. If damage is | |
| found, replace motor starter. If motor | |
| starter looks okay but is still suspect, | |
| you have two options: have a | |
| qualified electrician test the motor | |
| starter for function, or purchase a new | |
| starter and establish if that was the | |
| problem on changeout. | |
| If you have access to a voltmeter, you | |
Motor starter failure. | can separate a starter failure from a | |
motor failure by first, verifying | ||
| incoming voltage at | |
| second, checking the voltage | |
| between starter and motor at 220+/- | |
| 20. | |
| If incoming voltage is incorrect, you | |
| have a power supply problem. | |
| If voltage between starter and motor | |
| is incorrect, you have a starter | |
| problem. | |
| If voltage between starter and motor | |
| is correct, you have a motor problem. | |
|
| |
| If electric motor is suspect, you have | |
| two options: Have a qualified | |
Motor failure. | electrician test the motor for function | |
or remove the motor and take it to a | ||
| ||
| quality electric motor repair shop and | |
| have it tested. | |
|
| |
| Check to confirm all electrical | |
Miswiring of the unit. | connections are correct and properly | |
| tight. Make any needed corrections. | |
|
| |
| If the on/off switch is suspect, you | |
| have two options: Have a qualified | |
On/off switch failure. | electrician test the switch for function, | |
or purchase a new on/off switch and | ||
| ||
| establish if that was the problem on | |
| changeout. | |
|
|