1300W = 108 Amps total current draw

1300W = 108 Amps total current draw

12V

If the same amplifier is driven into a 2 ohm load, double it’s 4 ohm RMS rating. These amplifiers will effectively double their power at this load.

1000W X 1.3 X 2 = 2600 watts

2600W = 217 Amps total current draw

12V

If you are using more than one amplifier, add up the total current draw for all of them and choose the appropriate gauge based on the grand total.

POWER WIRE SIZE

A minimum of 8 gauge or a maximum of 4 gauge wire is recommended dependent on the application.

The ground wire must be the same gauge as the power wire.

11

Page 12
Image 12
Precision Power D2000/1, D3000/1, D500/1, D1000/1 manual 1300W= 108 Amps total current draw 12V