CONTROLS & CONNECTIONS 2
Clip - The LED labeled CLIP indicates at a signal level of +22dB. Care should be taken to avoid using signal levels that cause this LED to become active. Signal levels that reach or exceed this amount of output will cause undesirable artifacts (distortion) in the channel output signal that is being indicated by this LED. The signal level is reduced by rotating the channel’s control
Sample Rate Selector
The section at the extreme right of the front panel contains the sample rate selector switch with LED indicators provided for 32k, 44.1k and 48k. This section also contains a switch labeled EXT. CLOCK. When this switch is engaged the operating clock rate of 32k, 44.1, or 48k will be determined by the incom- ing signal from an external device through the word clock in input on the back panel of the DigiMAX LT.
4