OPERATING YOUR HEATER
Manual Control Models
nLIGHTINGn
INSTRUCTIONS
1.STOP! Read the safety information on the side of
heater.
2.Check that gas supply to heater is on.
3.Push in gas control knob
slightly and turn clockwise to the OFF position (see Figures 15&16).
4.Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step.
5.Push in gas control knob slightly and turn counter-
clockwise to“PILOT/IGN” and depress for five(5) seconds
NOTE: The first time that the heater
is operated after | connecting |
the gas supply , the | control knob |
should be depressed for about thirty (30) seconds. This will allow air to
b l e e d | f r o m | t h e | g a s |
system. |
|
|
|
6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.
7.Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7.
8.To select the desired heating level, partially press down the control knob slightly and rotate
counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.
nTO SELECTn
HEATING LEVEL
WARNING: When running heater,set control knob at ON, LOW, or HIGH locked positions(see Figures 18 & 19). Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Slightly press in control knob and turn counterclockwise to the ON, LOW or HIGH positions (see Figures 18 & 19).
Figure 15 - Control Knob In The OFF Position (MN060HPA)
Figure 16 - Control Knob In The OFF Position (MN100HPA)
Figure 17 - Pilot
MN060HPA
Figure 18 - Burner Patterns
Figure 19 - Burner Patterns
nTO TURN OFFn
GAS TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise
to the OFF position.
2.Turn off all electric power to the appliance if service is to be performed.
Shutting Off Burner Only (Pilot Stays Lit)
Turn control knob clockwise to the PILOT/IGN position.
nMANUAL LIGHTINGn
PROCEDURE
1.Remove lower front panel (see Figure 6 page 7)
2.Follow steps 1 through 5 under Lighting Instructions.
3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.Follow step 8 under Lighting Instructions.
5.Replace lower front panel.
1 1