INSTALLATION

OPERATING YOUR HEATER

CHECKING GAS

CONNECTIONS

WARNING: Test all gas piping

and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply

amixture of liquid soap and water to all joints. Bubbles form- ing show a leak. Correct all leaks at once.

Pressure Testing Gas Supply

Piping System

Test Pressures In Excess Of

1/2 PSIG (3.5 K Pa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping sys- tem by either using compressed air or opening

main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 13).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 14 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 10,11 and 12) Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, pages 11 and

12).

8.Replace lower front panel.

Figure 13-Equipment Shutoff Valve

nFOR YOUR SAFETYn

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result in causing property damage personal injury or loss of life.

A. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa)

1.Close equipment shutoff valve (see Figure 13).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Figure 14 -Checking Gas Joints

WARING:Do not over tighten gas connections.

explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1 0

Page 10
Image 10
Procom MN100HPA, MN100TPA, MN060HPA Operating Your Heater Checking GAS Connections, NFOR Your SAFETYn, Read Before Lighting