ProForm 795 user manual Top View, SYMPTOM The incline of the treadmill does not change correctly

Models: 795

1 36
Download 36 pages 43.52 Kb
Page 27
Image 27
Top

Locate the Reed Switch (52) and the Magnet (50) on the left side of the Pulley (49). Turn the Pulley until the Magnet is aligned with the Reed Switch.

Make sure that the gap between the Magnet and the Reed Switch is about 1/8 in. (3 mm). If necessary, loosen the #8 x 3/4" Tek Screw (14), move the Reed Switch slightly, and then retighten the Screw. Reattach the Motor Hood (not shown) and run the treadmill for a few minutes to check for a correct speed reading.

Top

View

52SYMPTOM: The incline of the treadmill does not change correctly 49

14 SYMPTOM: The walking belt slows when walked on50

1/8 in. Manual backgroundManual backgroundManual background

SYMPTOM: The incline of the treadmill does not change correctly

a.With the key in the console, press one of the Incline buttons. While the incline is changing, remove the key. After a few seconds, reinsert the key. The treadmill will automatically rise to the maximum incline level and then return to the mini- mum level. This will recalibrate the incline system.

SYMPTOM: The walking belt slows when walked on

a.Use only a single-outlet surge suppressor that meets all of the specifications described on page

15.

b.If the walking belt is overtightened, treadmill per- formance may decrease and the walking belt may become damaged. Remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller screws counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walk- ing belt is properly tightened.

b

2–3 in.

 

 

Idler Roller Screws

c.Your treadmill features a walking belt coated with high-performance lubricant. IMPORTANT: Never apply silicone spray or other substances to the walking belt or the walking platform unless in- structed to do so by an authorized service rep- resentative. Such substances may deteriorate the walking belt and cause excessive wear. If you suspect the walking belt needs more lubricant, see the front cover of this manual.

d.If the walking belt still slows when walked on, see the front cover of this manual.

27

Page 27
Image 27
ProForm 795 user manual Top View, SYMPTOM The incline of the treadmill does not change correctly