ProForm PCTL52580 user manual Maintenance and TROUBLE-SHOOTING, Problem The power does not turn on

Models: PCTL52580

1 19
Download 19 pages 42.76 Kb
Page 12
Image 12

MAINTENANCE AND TROUBLE-SHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at 1-888-963-4266, Monday through Friday, 8 a.m. until 6:30 p.m. Eastern Standard Time (excluding holidays).

PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor is plugged into a properly grounded outlet (see page 8). Use only a CUL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length.

b. After the power cord has been plugged in, make sure that the key is fully inserted into the con- sole.

c. Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

PROBLEM: The power turns off during use

c

Tripped

Reset

SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see c. above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in.

c. Remove the key from the console. Reinsert the key fully into the console.

d. If the treadmill still will not run, please call our Customer Service Department, toll-free.

PROBLEM: The displays of the console do not function properly

SOLUTION: a. Check the batteries in the console. See BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.

b. Remove the key from the console and

UPLUG THE

POWER CORD.

Remove the screws from the hood.

Locate the Reed Switch (86) and the Magnet (87) on

the left side of the Pulley (85). Turn the Pulley until the

Magnet is aligned with the Reed Switch.

Make sure

that the gap between the Magnet and the Reed

 

Switch is about 1/8”.

If necessary, loosen the Screw

(35)and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading.

b

 

1/8”

85

86

 

 

87

35

 

Top

 

View

 

12

Page 12
Image 12
ProForm PCTL52580 user manual Maintenance and TROUBLE-SHOOTING, Problem The power does not turn on, Switch is about 1/8