3.5 Dryer Transportation or Long-Term Storage
•Close inlet and outlet valves, switch off the devices (S1) and (ON/OFF), and disconnect power.
•Depressurize the air circuit using the condensate trap TEST button & remove the fill port plug to vent the reservoir.
•Drain the reservoir tank into a suitably sized container by removing right side panel (B) & turning drain valve (A) counter- clockwise.
•Replace the fill port plug & close the drain valve (A) by turning clockwise.
4.0MAINTENANCE
4.1Weekly
•Visually inspect for proper condensate drain operation.
4.2Monthly
•Isolate the dryer from the compressed air system by closing inlet & outlet valves and release pressure.
•Clean or replace condesate drain trap filter to remove any accumulated debris.
4.3Semi-annually
•Check compressor electrical current draw against amperage listed on the data plate.
•Remove power from the dryer and clean condenser finned surfaces with compressed air jet.
5.0EQUIPMENT DATA
Model |
|
|
| ||||||||||
Capacity (scfm)* |
| 18 | 30 | 60 |
| 75 |
| 100 | 120 | 150 | 200 | 250 | 250 |
Compressor Power (HP) |
| 1/6 | 1/4 | 1/3 |
| 1/2 |
| ¾ | 1 | 2 | 2 | ||
Power Supply (V/Ph/Hz) |
| 115/1/60 | 115/1/60 | 115/1/60 |
| 115/1/60 |
| 115/1/60 | 115/1/60 | 230/1/60 | 230/1/60 | 230/1/60 | 460/3/60 |
Rated Current (A) |
| 1.1 | 3.7 | 5.2 |
| 6.8 |
| 8.1 | 9.2 | 7.5 | 7.5 | 8.5 | 3 |
Full Load Current (A) |
| 2 | 4.6 | 6.8 |
| 8 |
| 9.8 | 11 | 8.7 | 10.5 | 12.5 | 5.2 |
Refrigerant Type |
|
|
| ||||||||||
Refrigerant Charge (LBS) |
| 0.66 | 0.79 | 1.21 |
| 1.21 |
| 1.21 | 1.32 | 1.75 | 2.16 | 2.0 | 2.0 |
Connection Size F (NPT) |
| 1/2 | 1/2 | 3/4 |
| 3/4 |
| ¾ | |||||
Weight (lbs) |
| 66 | 77 | 119 |
| 132 |
| 141 | 203 | 232 | 232 | 247 | 247 |
Max. Air Inlet (°F) |
| 113 | 113 | 113 |
| 113 |
| 113 | 113 | 113 | 113 | 113 | 113 |
Max. Ambient (°F) |
| 104 | 104 | 104 |
| 104 |
| 104 | 104 | 104 | 104 | 104 | 104 |
Max. Pressure (psig) |
| 230 | 230 | 230 |
| 230 |
| 230 | 230 | 230 | 230 | 230 | 230 |
| *Rated capacity @ air inlet of 100°F & 100 psig, 100°F ambient & 33 – 39° F leaving dewpoint |
|
| ||||||||||
|
|
|
|