54 QS2500
Standard 2 of 5
Read: Format
Maximum/Minimum Code Length: Same as Code 39. See page 35.
Truncate Leading/Ending: Same as UPC-A. See page 27.
Code ID Setting: Same as UPC-A. See page 27.
Insertion Group Selection: Same as UPC-A. See page 27.
Min. Code Length
Use Global Min. 00*
1–64 01–64
Truncate Leading
0–15 00–15
00*
Truncate Ending
0–15 00–15
00*
Code ID Setting
00–ffhex ASCII
code 00–ffhex<S>*
Insertion Group
Selection
0–44
00–44
00*
Format
Numeric only 00*
Full ASCII only 01

Option Bar Code Option Alphanumeric

Entry
Exit
Data Digits
(Variable)
Checksum1
(Optional)