06656 47
Code 2 of 5 Standard
Scan Option PF to disable Standard Code 2 of 5.
PF Disable Standard Code 2 of 5 *#@
Scan Option PG to enable Standard Code 2 of 5.
PG Enable Standard 2 of 5
The minimum length of Standard 2 of 5 messages is set by scanning
Option PH, followed by scanning two digits (01-32) from the Digit
Selection page.
The maximum length is set by scanning Option PI, followed by scan-
ning two digits (01-32) from the Digit Selection page. If the minimum
and maximum values are set equal, only codes of t hat exact length are
read. The minimum and maximum lengths must be even numbers.