PYLE Audio MN300HGA Operating Your Heater, THERMOSTAT MODEL MN300TGA, nLIGHTINGn INSTRUCTIONS

Models: MN300HGA

1 22
Download 22 pages 40.47 Kb
Page 11
Image 11
OPERATING YOUR HEATER

OPERATING YOUR HEATER

THERMOSTAT MODEL MN300TGA

nLIGHTINGn

INSTRUCTIONS

1.STOP! Read the safety information on the side of heater.

2.Check that gas supply to heater is on.

3.Push in gas control knob

slightly and turn clockwise THERMOSTAT MODEL MN300TGA to the OFF position.

NOTE: knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

4.Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step.

5.Push in gas control knob

slightly and turn nLIGHTINGn counter-

clockwise

to

the “PILOT/IGN”

position

and

depress

for

five(5) seconds

 

 

NOTE:

The

first

time that

the

h eater

is

op erated after

connecting the gas supply , the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

NOTE: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for thirty (30) seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

NOTE: If pilot goes out, repeat steps 3 through 7. Wait one (1) minute before lighting pilot again

8. Turn

control

knob

counterclockwise

to

desired

heating

Level. The

main burner should light. Set control knob to any heat level between HI and LO.

Figure 16 - Control Knob in The OFF Position
Figure 17 - Pilot

nTHERMOSTATn

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner.The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner.

This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room tem- perature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.

NOTE: the thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending o n h o u sin g c o n s tr u c t io n . installation location, room size, open air temperatures, etc.). frequent use of your heater will let you determine your own comfort levels.

nTO TURN OFFn

GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise

Figure 16 - Control Knob in The OFF Position to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

Turn control knob clockwise Figure 17 - Pilot to the PILOT/IGN position

nMANUAL LIGHTINGn

PROCEDURE

1.Remove lower front panel (see Figure 7 page 7).

2.Follow steps 1 through 5 under Lighting Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace lower front panel.

1 1

Page 11
Image 11